Technical resources: 26 standards · 9 calculators · metric & imperial
Contact
Reference data

Bolt hole sizes

Nominal hole dimensions for standard, oversized and slotted holes in the US (AISC 360 Table J3.3) and for normal and oversize holes in Europe (EN 1090-2).

Bolt hole sizes

AISC 360 Table J3.3: nominal hole dimensions
Bolt dia.StandardOversizedShort slot (W × L)Long slot (W × L)
12.7 mm14.29 mm15.88 mm14.29 mm × 17.46 mm14.29 mm × 31.75 mm
15.88 mm17.46 mm20.64 mm17.46 mm × 22.22 mm17.46 mm × 39.69 mm
19.05 mm20.64 mm23.81 mm20.64 mm × 25.4 mm20.64 mm × 47.63 mm
22.22 mm23.81 mm26.99 mm23.81 mm × 28.58 mm23.81 mm × 55.56 mm
25.4 mm26.99 mm31.75 mm26.99 mm × 33.34 mm26.99 mm × 63.5 mm
28.58 mm30.16 mm36.51 mm30.16 mm × 38.1 mm30.16 mm × 71.44 mm
31.75 mm33.34 mm39.69 mm33.34 mm × 41.28 mm33.34 mm × 79.38 mm
34.93 mm36.51 mm42.86 mm36.51 mm × 44.45 mm36.51 mm × 87.31 mm
38.1 mm39.69 mm46.04 mm39.69 mm × 47.63 mm39.69 mm × 95.25 mm
EN 1090-2: nominal clearance for metric bolts
BoltNormal hole dia.Oversize hole dia.
M1213 mm15 mm
M1415 mm18 mm
M1618 mm20 mm
M2022 mm24 mm
M2224 mm26 mm
M2426 mm30 mm
M2730 mm35 mm
M3033 mm38 mm
M3639 mm44 mm

Nominal hole dimensions for bolts in structural steel. Use of oversized and slotted holes is restricted by the design code and the RCSC Specification (washer requirements, direction of slots, slip-critical limits). Anchor rod holes in base plates are larger: see AISC Design Guide 1.

Prepared from the published tables of the standards named and cross-checked against secondary references. It is a working reference, not a substitute for the standard: confirm against the current edition before using it in design, specification or procurement.

Ready to get a quotation?