Structural bolt pretension and torque

AISC minimum pretension for A325 and A490 bolts, and the torque estimate to reach it from T = K × D × P.

Torque & preload calculator

Structural bolt pretension and torque

Nut factor K
DiameterA325 pretension (kN)A325 torque (N·m)A490 pretension (kN)A490 torque (N·m)
12.7 mm (1/2")5313667169
15.88 mm (5/8")85268107339
19.05 mm (3/4")125475156593
22.22 mm (7/8")173771218969
25.4 mm (1")2271,1522851,446
28.58 mm (1-1/8")2491,4243562,034
31.75 mm (1-1/4")3162,0054542,881
34.93 mm (1-3/8")3782,6415383,760
38.1 mm (1-1/2")4583,4916585,017

Torque is a poor proxy for tension: the nut factor K varies with lubrication, coating and thread condition. Structural joints should be tightened by turn-of-nut, calibrated wrench, twist-off bolts or DTI washers as the specification requires. For other grades and a custom K use the torque and preload calculator.

Prepared from the published tables of the standards named and cross-checked against secondary references. It is a working reference, not a substitute for the standard: confirm against the current edition before using it in design, specification or procurement.