Technical resources · Calculator
Anchor rod steel strength (ACI 318)
Steel tension and shear strength of a cast-in headed or hooked anchor rod, with the ductility check ACI 318 uses to classify the steel.
φNsa tensionkN
φVsa shearkN
Ase (stress area)mm²
Ductile steel element: 21 % elongation, 30 % reduction of area, so the φ factors above apply.
Show the numbers
- Ase,N = 391 mm² (UNC threads per inch)
- futa = min(specified Fu 517 MPa, 1.9 fya 721 MPa, 862 MPa) = 517 MPa
- Nsa = Ase · futa = 202.1 kN; φNsa = 0.75 · Nsa = 151.6 kN
- Vsa = 0.6 · Ase · futa = 121.3 kN; φVsa = 0.65 · Vsa = 78.8 kN
Steel strength only. Concrete breakout, pullout, side-face blowout, pryout, edge distance, spacing and seismic provisions are separate checks under ACI 318 Chapter 17 (or AISC Design Guide 1 for column bases) and are NOT covered here. This is a screening aid, not a design.
Need it supplied or checked?
Build a list of products and quantities, or send a sketch or a drawing. Our sales team replies with a quotation.