What the anchor bolt plan should state
- Specification and grade: for example ASTM F1554 Grade 55, with Supplementary Requirement S1 if the rod will be welded.
- Diameter, overall length, and the projection above the concrete or grout.
- The embedded end: heavy hex nut, plate washer, headed, or bent (L or J). Say which; a bend is not an equivalent of a nut-and-washer end.
- Thread length at the top, and the thread series. Common practice is coarse (UNC) to 1 in. and 8-UN above 1 in.; state the series rather than assuming it.
- Finish: plain, or hot-dip galvanized to ASTM F2329, and whether the whole rod or only the projecting part is coated.
- The nut and washer grades: for Grade 36 and 55 rods, A563 Grade A heavy hex is typical; for Grade 105, A563 Grade DH. Add leveling nuts and plate washers if the base plate is shimmed on nuts.
- Placement tolerance and template requirements, by reference to the AISC Code of Standard Practice or the project specification.
Mistakes that show up on site
- Thread series left open, so one supplier ships UNC and another 8-UN, and the nuts do not match.
- Galvanized rods with plain nuts, or galvanized nuts that were not overtapped. Order nuts and rods as a matched set.
- Welding Grade 105 rod. It is not a weldable grade; specify Grade 55 with S1 if welding is needed.
- Counting on a hook to carry tension. The pullout capacity of a hooked bolt is limited by ACI 318; use a nut-and-washer or headed end for tension-critical anchors.
- Rod too short after allowing for grout, leveling nut, base plate, top nut and washer, and two threads showing. The bolt length calculator in the library does this arithmetic.
What the rod standard does not check
ASTM F1554 defines the steel. It says nothing about the concrete. Breakout, pullout, side-face blowout and pryout are design checks under ACI 318 Chapter 17 (or AISC Design Guide 1 for column bases). The anchor rod strength calculator gives the steel strength only, to use alongside those checks.
Prepared from the published tables of the standards named and cross-checked against secondary references. It is a working reference, not a substitute for the standard: confirm against the current edition before using it in design, specification or procurement.